CPAP Ranker

Nasal

ResMed AirTouch N20

The AirTouch N20 uses the AirFit N20 frame and magnetic headgear with an UltraSoft memory foam cushion. ResMed recommends replacing this cushion every month, with no daily cleaning.

Product photo coming soon

N20 nasal mask with a foam cushion

Strengths

  • Memory foam cushion as an alternative to silicone.
  • No daily cushion washing: ResMed recommends a new cushion every month.
  • Compatible with the ResMed AirMini and with the AirFit N20 silicone cushion.

Watch out for

  • Magnets in the frame and headgear clips: contraindicated if you or your bed partner has certain implants, and a 150 mm safety distance applies.
  • Consumable cushion: monthly replacement, never submerged or cleaned with household products.
  • The cushion covers the bridge of the nose.

Best for

  • Sensitive skin (a profile highlighted by ResMed)
  • Side sleepers (a profile highlighted by ResMed)
  • Nose breathers who keep their mouth closed

CPAP Ranker analysis: editorial, written from the manufacturer's documents, sources at the bottom of the page. It is not a patient review.

Buy from our partner

VRVivaRespireBelgian shop, ships across Europe
View the AirTouch N20

CPAP Ranker is funded by VivaRespire. That partnership has no influence on ratings or reviews.

Do you use it?

Review the AirTouch N20 and earn 25 points.

Rate this product

Manufacturer warning: magnets

Magnets sit in the frame and the lower headgear clips (field strength up to 400 mT) and may detach during sleep. Contraindicated if you, or anyone in close physical contact while the mask is in use (such as a bed partner), has an active implant that interacts with magnets (pacemaker, implantable cardioverter defibrillator, neurostimulator, cerebrospinal fluid shunt, insulin or infusion pump) or a metallic implant or object containing ferromagnetic material (aneurysm clip, embolic coils, stents, valves, electrodes, hearing or balance implant with magnets, ocular implant, metal splinter in the eye). Keep the magnets at least 150 mm (6 inches) away from any implant or medical device that could be affected. ResMed's Field Safety Notice of 20 November 2023 raised this distance from 50 mm to 150 mm and broadened the contraindications; ResMed updated the labeling rather than withdrawing the mask, and the FDA classified the action as a Class I recall in the United States.

Read the official safety notice

What patients say

Specifications

Data published by the manufacturer, checked in its user guides. A missing field means the information was not found.

Sizes
S, M, L
Cushion material
memory-foam (UltraSoft)
Declared noise
16 dBA at 1 m · 24 dBA sound power
Magnets
Yes
Top-of-head tube
No
Nose bridge
Covered by the mask
AirMini compatible
Yes
Launch year
2020
8 sources consulted

An error, outdated information? Tell us through the feedback button and we will fix it.